Skip to Content
Kenall 2026

Herculux for Institutional High Abuse

H69-D_HS01.png

H69-D

Key Features

  • Surface wall mount – nominal 6"W×9"L×7"D
  • Heavy die-cast aluminum housing
  • UV-stabilized, injection molded polycarbonate lens
  • Stainless steel Torx® fasteners
  • Available 590nm Native Amber for wildlife or spectrally sensitive applications

Documents

Specifications are subject to change without notice. Please consult your Kenall Customer Service for help with special requests at (800) 4 Kenall.

Applications

  • Parks and Recreation
  • Multifamily Housing
  • Walkways
  • Restrooms
  • Stairwells
  • Schools and Universities
  • Corridors
  • Exteriors and Entryways

Lens Types

  • Clear Prismatic Polycarbonate
  • Pearlescent Polycarbonate

Lamp Types

  • LED

Sizes

  • 6"x9"

Listings

  • UL-CULWet
  • POMG
  • IK10

Related Technologies

Praesent neque felis, tincidunt et bibendum at, ultricies nec augue. Nunc a elit sodales, efficitur turpis ac, facilisis diam. Donec eu enim in mi tempus consequat. Duis in massa laoreet, venenatis massa in, condimentum est.

Narrow Spectrum Technology

Narrow Spectrum Lighting

Targeted wavelength solutions designed to support specialized research, manufacturing, and clinical applications where spectral precision matters.

Explore

View All Technologies

Technical Specifications

Electrical
Available in 3500K, 4000K, and 5000K color temperatures, 80 CRI. Available 590nm native amber for wildlife-sensitive applications. 120-277VAC or 347VAC, 50/60Hz electrical input with high power factor electronic, constant-current driver (>.90 PF).  Standard 0-10V dimming with 1-100% range; maximum driver source of 200 µA. 
Gasket
Die-cut closed cell neoprene gasket seals die-cast housing to mounting surface. Refractor inset into housing and sealed to integral ledge with one “O” ring closed cell silicone gasket.
Hardware
Four captive stainless steel Torx® with center pin fasteners secure refractor/eyelid to housing. Shoulder fastener design and washer prevent refractor/eyelid stress due to over torquing.
Housing
One-piece heavy duty die-cast, low-copper aluminum housing. Housing flange interlocks around refractor producing maximum moisture deflection and resistance to prying. Housing provided with four standoff mounting holes. One 1/2" IPS tapped hole on back of housing. Two 1/2" IPS tapped and plugged holes on sides of housing – see Cross Section/Details. Standard housing in dark bronze TGIC polyester powder coat – 5-stage pre-treatment.
Installation
Wall mount standard fixture must be installed lamp base up. Standard fourpoint mounting required for Peace of Mind Guarantee®. Fixture with Horizontal Internal Shield option (ISH) may be installed in horizontal position.
Lens
One-piece internal-prismatic refractor (UV-stabilized, high impact, virgin injection molded polycarbonate). Nominal thickness .125".
Listings
UL and CUL listed for Wet Location. Luminaire tested to an IK10 impact protection rating per IEC 60068-2-75:1997-08. 
Reflector
High efficiency textured aluminum.

Downloads

Product Documentation

Installation Files

Photometry (IES)

REVIT Files

Additional Resources

Ready to Specify?

From the show floor to your facility, we believe the best relationships start with a handshake. That's why you'll find our team at trade shows and industry events all year long.

Contact Us

This product is able to comply with the latest domestic preference legislation, such as the Buy American Act (BAA), Trade Agreement Act (TAA), Build America, Buy America Act (BABA), and others.

Explore Related Applications

Corridors & Stairwells

Corridors & Stairwells

Lighting in intermittently occupied areas, when controlled with occupancy sensors, provides significant cost savings without sacrificing safety or performance. Kenall offers a line of occupancy sensing, Wet Location, and IP-certified products with our exclusive Peace of Mind Lifetime Guarantee® against breakage for use in corridors and stairwells, where the energy savings potential is substantial.

Explore

Nurse Stations | Corridors

Nurse Stations | Corridors

As the operational hub of the unit, nurses’ stations require lighting that supports clinical tasks, observation, and communication. Frequently occupied by patients, they function as extensions of the therapeutic environment. Kenall lighting ensures these areas are safe and supportive while providing the visibility, durability and security required for optimal patient care.

Explore

Patient Bathrooms

Patient Bathrooms

Behavioral health bathrooms are among the most safety-critical spaces. Lighting design must prioritize patient safety and ligature-resistant protection while preserving comfort and dignity. Kenall bathroom lighting combines the safety requirements of a high-risk patient environment with the visual comfort and dignity of a residential bathroom, helping patients feel secure and supported during daily personal-care activities.

Explore

Stairwells

Stairwells

Hospital stairwells are life-safety spaces first and circulation spaces second. Lighting must support visual comfort, safe movement, emergency egress, security, and code compliance; ensuring occupants can safely navigate stairs during normal operation and emergency evacuation. Kenall’s Millenium® series luminaires offer an attractive solution when performance, aesthetics, maintenance, durability and energy efficiency matter most.

Explore