Key Features

  • Recessed wall mount – Single Face
  • Indirect Red or Green LED
  • Self diagnostic testing features
  • One-piece seam welded housing
  • 304 stainless steel overlapping doorframe

Documents

Specifications are subject to change without notice. Please consult your Kenall Customer Service for help with special requests at (800) 4 Kenall.

Applications

  • Packaging and Staging
  • Biosafety and Containment
  • Isolation Areas
  • Corridors
  • Vivariums
  • Cleanrooms
  • Containment Areas
  • Laboratories
  • Research and Development
  • Exit

Lamp Types

  • LED

Listings

  • IP65
  • ISO5Cleanroom100
  • LED
  • NSF2
  • UL-CULWet
  • NFPA
  • UL924
  • BSL1-4
  • BABA

Have A Question?

We're Here To Help. Whether you're specifying a project, troubleshooting an existing installation, or just need technical guidance, our team is ready to assist. Reach out and we'll connect you with the right expert.

Contact Us

Technical Specifications

Doorframe
20-gauge type 304 stainless steel (#4 finish-post fabrication) standard – see ordering information. One-piece 60° beveled perimeter construction. Continuous angle lens retention system. Mechanical guide for doorframe fastener alignment. Doorframe secured to housing with 4 captive flush mounted Phillips head stainless steel fasteners.
Doorframe Gasket
One-piece closed cell extruded silicone gasket seals doorframe to housing and wall structure.
Electrical
624 nm Red or 527 nm Green LED light source. Electrical components mounted to removable high impact, injection molded polycarbonate chassis. Exit Ready – can power one Kenall METSS Satellite Exit.
Housing
20-gauge CRS standard – see ordering information. Hole-free one-piece seam welded construction. White TGIC polyester powder coat finish – 5 step pre-treatment. Salt spray test: 1,000 hours; Reflectance: 92%.
Legend
Legend illuminated by internal high output LEDs. Lettering six inches high with .750" stroke. Polycarbonate red or green filter panels. High impact, punched, formed and painted sheet metal stencil and field selectable chevron inserts.
Lens
.125" clear polycarbonate lens sealed to perimeter ledge of lens aperture with silicone sealant and secured with continuous lens retention system.
Listings
UL and CUL Listed for Wet Location. UL certified IP65 per IEC 60598. NSF2 Splash and Non-Food Zone. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements. FED-STD-209E/Class 100 (ISO 5) Cleanrooms. Suitable for biosafety labs rated BSL 1 thru 4. Build America, Buy America Act compliant.
Options
Sealed nickel-cadmium Emergency Battery Pack (EL) with standard deep cycle battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected mechanical test switch and status indicator. Provides 120 minutes of emergency operation. Emergency Battery Pack (EL) suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery Pack (CEL) suitable for -45°C to 45°C (-49°F to 113°F). (When used with a Kenall METSS, this fixture provides 90 minutes of emergency operation.)
Patent
U.S. Patent No. 5, 902, 035.

Downloads

Product Documentation

Installation Files

Additional Resources

Ready to Specify?

From the show floor to your facility, we believe the best relationships start with a handshake. That's why you'll find our team at trade shows and industry events all year long.

Contact Us

This product is able to comply with the latest domestic preference legislation, such as the Buy American Act (BAA), Trade Agreement Act (TAA), Build America, Buy America Act (BABA), and others.

Explore Related Applications

Labratories

Labratories

Educational laboratories place much greater demands on lighting than standard classrooms. Students perform detailed visual tasks, work with equipment, read instruments, conduct experiments, and often handle potentially hazardous materials. As a result, lighting must prioritize visibility, accuracy, safety, and flexibility. Kenall SimpleSeal® series and related technologies, including vivarium lighting, helps student research yield reliable results.

Explore

Nurse Stations | Corridors

Nurse Stations | Corridors

As the operational hub of the unit, nurses’ stations require lighting that supports clinical tasks, observation, and communication. Frequently occupied by patients, they function as extensions of the therapeutic environment. Kenall lighting ensures these areas are safe and supportive while providing the visibility, durability and security required for optimal patient care.

Explore

Research & Biosafety Labs

Research & Biosafety Labs

Due to the hazardous nature of the work performed, research and biosafety labs require lighting that balances scientific accuracy, safety, visual comfort, contamination control, and regulatory compliance.

Complementary Products

Complementary Products

Successful lighting projects extend beyond occupied spaces. Stairwells, building exteriors, parking areas, and exit & emergency zones all play a critical role in safety, security, and patron confidence while supporting code compliance and operational continuity.

Explore