Key Features

  • Recessed ceiling mount; grid or flange - 1'×4', 2'×2', 2'×4'
  • Delivers greater than 90 CRI without sacrificing efficacy
  • Evenly illuminated diffuser provides reduced glare and surface brightness
  • Low-profile housing fits in tight spaces — only 2.5” deep
  • One piece inset doorframe, secured to housing with aircraft cables

Documents

Specifications are subject to change without notice. Please consult your Kenall Customer Service for help with special requests at (800) 4 Kenall.

Applications

  • Pharmaceutical
  • Kitchen and Food Prep
  • Biosafety and Containment
  • Anterooms
  • Vivariums
  • Cleanrooms
  • Containment Areas
  • Laboratories
  • Research and Development
  • Natatoriums
  • Meat Processing Facilities

Lamp Types

  • LED

Sizes

  • 1'x4'
  • 2'x2'
  • 2'x4'

Listings

  • IP65
  • LED
  • NSF2
  • UL-CULWet
  • CCEA
  • ETL
  • FNoption
  • ISO3Class1
  • BSL1-2
  • Declare
  • BABA

Related Technologies

Praesent neque felis, tincidunt et bibendum at, ultricies nec augue. Nunc a elit sodales, efficitur turpis ac, facilisis diam. Donec eu enim in mi tempus consequat. Duis in massa laoreet, venenatis massa in, condimentum est.

Narrow Spectrum Technology

Narrow Spectrum Lighting

Targeted wavelength solutions designed to support specialized research, manufacturing, and clinical applications where spectral precision matters.

Explore

Tunable White

Tunable White

Dynamic white light technology with adjustable color temperature and intensity to support occupant comfort, focus, and well-being throughout the day.

Explore

View All Technologies

Technical Specifications

Controls
Optional embedded microwave sensor (MS) mounted behind diffuser. Factory default is 30% dimming and 20min. timeout. Custom settings available upon request.  Sensor operates at 5.8GHz (continuous wave radar) and provides 360° coverage.  Other Wattstopper or third-party control options available upon request. 
Doorframe
 Standard one-piece, 20-gauge cold-rolled steel with inset-style construction and seam-welded corners. Optional Type 304 stainless steel in 4B brushed finish or painted aluminum. Gloss white TGIC polyester powder coat finish with 5-stage pre-treatment. Doorframe secured to housing with galvanized steel aircraft cables and captive, flush-mounted Phillips-head fasteners. Closed-cell silicone gasket seals doorframe to housing.
Driver
120-277VAC or 347VAC, 50/60Hz electrical input with serviceable constant-current drivers (<20% THD, >0.90 PF).  Minimum 85% driver efficiency.  Standard 0-10V dimming with 1-100% range and dim-to-dark capabilities. 0.4mA maximum driver source current. Optional 0.1-100% range with dim-to-dark capabilities.  Consult factory for DALI availability.
Housing
Constructed of die-formed, fully seam-welded 24-gauge cold rolled steel as standard. Optional 20-gauge CRS, 304 stainless or .050" aluminum.  18-gauge housing flange with mitered and welded-corners in matching material type. White TGIC polyester powder coat finish – 5-step pre-treatment. Salt spray test: 1,000 hours; Reflectance: 92%.
Installation
Suitable for recessed ceiling installation in specified grid or drywall (flange) ceiling types. Grid installation suitable for 15/16", 1" and 1.5" wide T-bar ceilings. Includes integral grid brackets designed for lay‑in applications with nominal T‑bar heights of 1.5", 1-11/16", and 2". Refer to installation instructions for additional details. The construction can accommodate other T‑bar heights when means of attachment to the structure are provided by others. Flange constructions shall be specified for total ceiling thicknesses (including structure) of 1.30"-2.20" (F1) or 2.10"-3.00" (F2). See Options for continuous row mounting and install frames. Gasketed wire access panel on rear of housing allows electrical connections without door removal; includes one 7/8" hole and one 7/8" knockout. Suitable for -30°C to 40°C ambient environments, unless otherwise noted.
LED Module
Serviceable back-lit LED array.  Standard 90 CRI min. (R9 > 50).  See Ordering Information for available color temperature options.  3 SDCM color variation max.
Listings
Luminaire is certified to UL standards by Intertek Testing Laboratories for recessed ceiling insulation contact (IC-rated) and Indoor Wet Location installations.. Certified IP65 per IEC 60598. Certified NSF2 Splash Zone. CCEA Approved. Suitable for biosafety labs rated BSL 1 and 2. Meets FED-STD-209E/Class 1 (ISO 3) Cleanrooms. Suitable for EU GMP Grade A cleanrooms. CSEDI is participating in Declare. Build America, Buy America Act compliant.
Lumen Data
Optics
High-impact diffuse acrylic lens, nominal .125" thick.  Continuous seal to perimeter of door aperture with RTV silicone and mechanical retention bracketry.
Photometrics
Photometry tested to the IESNA LM-79-08 standard. For additional photometric data, please go to www.kenall.com.
Warranty
Limited five (5) year warranty.

Downloads

Product Documentation

Installation Files

Photometry (IES)

REVIT Files

Additional Resources

Ready to Specify?

From the show floor to your facility, we believe the best relationships start with a handshake. That's why you'll find our team at trade shows and industry events all year long.

Contact Us

This product is able to comply with the latest domestic preference legislation, such as the Buy American Act (BAA), Trade Agreement Act (TAA), Build America, Buy America Act (BABA), and others.

Explore Related Applications

Labratories

Labratories

Educational laboratories place much greater demands on lighting than standard classrooms. Students perform detailed visual tasks, work with equipment, read instruments, conduct experiments, and often handle potentially hazardous materials. As a result, lighting must prioritize visibility, accuracy, safety, and flexibility. Kenall SimpleSeal® series and related technologies, including vivarium lighting, helps student research yield reliable results.

Explore

Research & Biosafety Labs

Research & Biosafety Labs

Due to the hazardous nature of the work performed, research and biosafety labs require lighting that balances scientific accuracy, safety, visual comfort, contamination control, and regulatory compliance.