Skip to Content
Kenall 2026

Millenium Metrex Exit & Emergency

METSR Main Image

METSR

Key Features

  • Semi-recessed wall mount – Single Face
  • Indirect Red or Green LED
  • Internal Battery Backup System
  • 20-gauge cold rolled steel housing
  • Self diagnostic testing features
  • Suitable for behavioral health use in supervised, medium-risk areas

Documents

Specifications are subject to change without notice. Please consult your Kenall Customer Service for help with special requests at (800) 4 Kenall.

Applications

  • Parks and Recreation
  • Packaging and Staging
  • Multifamily Housing
  • Cafeterias
  • Restrooms
  • Stairwells
  • Foyers and Lobbies
  • Corridors
  • Gymnasiums and Multipurpose Rooms
  • Exit

Lamp Types

  • LED

Listings

  • IP65
  • LED
  • UL-CULWet
  • NFPA
  • POMG
  • UL924

Have A Question?

We're Here To Help. Whether you're specifying a project, troubleshooting an existing installation, or just need technical guidance, our team is ready to assist. Reach out and we'll connect you with the right expert.

Contact Us

Technical Specifications

Electrical
624 nm Red or 527 nm Green LED light source. Electrical components mounted to removable high impact, injection molded polycarbonate chassis. Remote Exit Ready – can power one Kenall METSS Satellite Exit.
Fasteners
Hardened security screws as specified – see ordering information.
Finish
TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test: 1,000 hours; Reflectance: 92%. See Options for black exterior.
Frame
One-piece die-formed prime grade 16-gauge material as specified – see Ordering Information. Corners continuously seam welded and smooth with no post grinding (TIG).
Housing
20-gauge CRS. Hole-free one-piece seam welded construction.
Legend
Legend illuminated by internal high output LEDs. Lettering six inches high with .750" stroke. Polycarbonate red or green filter panels. High impact, punched, formed and painted sheet metal stencil and field selectable chevron inserts.
Lens
External panel .188 inch thick clear polycarbonate.
Listings
UL and CUL listed for Wet Location. UL certified IP65 in compliance with IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements. 
Options
Sealed nickel-cadmium Emergency Battery Pack (EL) with standard deep cycle battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected mechanical test switch and status indicator. Provides 120 minutes of emergency operation. Emergency Battery Pack (EL) suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery Pack (CEL) suitable for -45°C to 45°C (-49°F to 113°F). (When used with a Kenall METSS, this fixture provides 90 minutes of emergency operation.)

Downloads

Product Documentation

Installation Files

REVIT Files

Additional Resources

Ready to Specify?

From the show floor to your facility, we believe the best relationships start with a handshake. That's why you'll find our team at trade shows and industry events all year long.

Contact Us

This product is able to comply with the latest domestic preference legislation, such as the Buy American Act (BAA), Trade Agreement Act (TAA), Build America, Buy America Act (BABA), and others.

Explore Related Applications

Cafeterias

Cafeterias

Healthcare cafeteria lighting should create a comfortable, welcoming environment while supporting safety and visibility. Effective designs combine balanced ambient illumination, low glare, warm color temperatures, and high color rendering for appetizing food appearance. Daylight integration and energy-efficient controls help enhance the experience for patients, visitors, and staff while also supporting wellness goals.

Explore

Corridors & Stairwells

Corridors & Stairwells

Lighting in intermittently occupied areas, when controlled with occupancy sensors, provides significant cost savings without sacrificing safety or performance. Kenall offers a line of occupancy sensing, Wet Location, and IP-certified products with our exclusive Peace of Mind Lifetime Guarantee® against breakage for use in corridors and stairwells, where the energy savings potential is substantial.

Explore

Dining Areas

Dining Areas

A behavioral health dining room is often one of the primary spaces for socialization, routine-building, behavioral observation, and therapeutic interaction. Lighting should promote a calm, welcoming atmosphere while supporting safety, visibility, and operational requirements. Support social connection, routine, dignity, and recovery with Kenall’s dining area lighting.

Explore

Nurse Stations | Corridors

Nurse Stations | Corridors

As the operational hub of the unit, nurses’ stations require lighting that supports clinical tasks, observation, and communication. Frequently occupied by patients, they function as extensions of the therapeutic environment. Kenall lighting ensures these areas are safe and supportive while providing the visibility, durability and security required for optimal patient care.

Explore

Patient Bathrooms

Patient Bathrooms

Behavioral health bathrooms are among the most safety-critical spaces. Lighting design must prioritize patient safety and ligature-resistant protection while preserving comfort and dignity. Kenall bathroom lighting combines the safety requirements of a high-risk patient environment with the visual comfort and dignity of a residential bathroom, helping patients feel secure and supported during daily personal-care activities.

Explore

Stairwells

Stairwells

Hospital stairwells are life-safety spaces first and circulation spaces second. Lighting must support visual comfort, safe movement, emergency egress, security, and code compliance; ensuring occupants can safely navigate stairs during normal operation and emergency evacuation. Kenall’s Millenium® series luminaires offer an attractive solution when performance, aesthetics, maintenance, durability and energy efficiency matter most.

Explore

Complementary Products

Complementary Products

Successful lighting projects extend beyond occupied spaces. Stairwells, building exteriors, parking areas, and exit & emergency zones all play a critical role in safety, security, and patron confidence while supporting code compliance and operational continuity.

Explore