Skip to Content
Kenall 2026

Millenium Stretch

MLHA5S Main Image

MLHA5S

Key Features

  • Surface mount – ceiling or wall; 5"×48"
  • Extruded aluminum housing with decorative end caps
  • Low-profile –ADA compliant
  • Peace of Mind Guarantee® against breakage

Documents

Specifications are subject to change without notice. Please consult your Kenall Customer Service for help with special requests at (800) 4 Kenall.

Applications

  • Parks and Recreation
  • Kitchen and Food Prep
  • Locker Rooms
  • Multifamily Housing
  • Walkways
  • Washrooms (Correctional)
  • Restrooms
  • Stairwells
  • Showers
  • Schools and Universities
  • Transportation Platforms
  • Foyers and Lobbies
  • Corridors
  • Sally Ports
  • Exteriors and Entryways
  • Gymnasiums and Multipurpose Rooms
  • Natatoriums

Lens Types

  • Clear Prismatic Polycarbonate
  • Pearlescent Polycarbonate

Lamp Types

  • LED

Sizes

  • 5"W

Listings

  • ADA
  • IP64
  • LED
  • UL-CULWet
  • POMG
  • IK10

Have A Question?

We're Here To Help. Whether you're specifying a project, troubleshooting an existing installation, or just need technical guidance, our team is ready to assist. Reach out and we'll connect you with the right expert.

Contact Us

Technical Specifications

Electrical
Available 3500K, 4000K and 5000K color temperatures, 82 CRI. 120-277VAC and 347VAC, 50/60Hz electrical input with serviceable high power factor electronic, constant-current driver (<20% THD, >0.95 PF). Standard 0-10V dimming with 1-100% range and dim-to-dark capabilities; maximum driver source of 165μA. Consult factory for flourescent options.
End Caps/Bands
Marine grade die-cast aluminum. Four end cap styles available: Flat, Rounded, Reveal and Stepped. Conduit/Wiremold™ knockout visible only from interior of end cap (for Flat and Rounded styles only).
Hardware
Four stainless steel, tamper-resistant Torx® with center pin fasteners secure lens in housing body's lens channel.
Housing
Marine grade aluminum. Extruded body with die-cast end caps. Housing, with end caps, post assembly TGIC polyester powder coat finished – 5-step pre-treatment. See Ordering Information for standard, optional, architectural and custom finishes. Each linear run of luminaires consists of one Beginning of Run Luminaire (B), one or multiple Middle Luminaire(s) (M), and one End of Run Luminaire (E). Specify and/or order systems per linear run (i.e. (1)B48, (5)M48, (1)E48). NOTE: Contact factory for custom lengths.
Installation
Standard four-point mounting per fixture required for Peace of Mind Guarantee®.
Lens
UV-stabilized, high impact extruded clear or pearlescent polycarbonate. Smooth exterior, linear prismatic interior. Nominal thickness .156". Lens securely positioned in body channels and end caps. Lens locked in place with tamper-resistant stainless steel Torx® with center pin fasteners and sealed with closed cell gaskets.
Listings
Listed to UL Wet Location IP64 per IEC 60598 – ceiling mount. Corner, horizontal wall, vertical wall and pendant mount installation – damp location only. ADA compliant. Photometry tested to the IESNA LM-79-08 standard by an ILAC / ISO17025 accredited laboratory. Luminaire tested to an IK10 impact protection rating per IEC 60068-2-75:1997-08. 
Patent
No. 6,984,055; No. 7,494,241; No. 8,550,656.
Reflector
Full reflector/wire cover – 92% reflectivity.
Sockets
Shock-resistant sockets with internal locking collar to ensure positive lamp retention.
Warranty
Limited ten (10) year warranty for LED Lamps.

Downloads

Product Documentation

Installation Files

REVIT Files

Additional Resources

Ready to Specify?

From the show floor to your facility, we believe the best relationships start with a handshake. That's why you'll find our team at trade shows and industry events all year long.

Contact Us

This product is able to comply with the latest domestic preference legislation, such as the Buy American Act (BAA), Trade Agreement Act (TAA), Build America, Buy America Act (BABA), and others.

Explore Related Applications

Corridors & Sally Ports

Corridors & Sally Ports

When lighting corridors and sally ports, the priorities extend beyond visibility; security, safety, durability, surveillance, and operational control are primary design drivers. The lighting quality must ensure safety during detainee/inmate transfers and transitions. Kenall’s MightyMac® & Millenium® luminaires with high abuse construction are ideal for these transitional spaces.

Explore

Corridors & Stairwells

Corridors & Stairwells

Lighting in intermittently occupied areas, when controlled with occupancy sensors, provides significant cost savings without sacrificing safety or performance. Kenall offers a line of occupancy sensing, Wet Location, and IP-certified products with our exclusive Peace of Mind Lifetime Guarantee® against breakage for use in corridors and stairwells, where the energy savings potential is substantial.

Explore

Nurse Stations | Corridors

Nurse Stations | Corridors

As the operational hub of the unit, nurses’ stations require lighting that supports clinical tasks, observation, and communication. Frequently occupied by patients, they function as extensions of the therapeutic environment. Kenall lighting ensures these areas are safe and supportive while providing the visibility, durability and security required for optimal patient care.

Explore

Patient Bathrooms

Patient Bathrooms

Behavioral health bathrooms are among the most safety-critical spaces. Lighting design must prioritize patient safety and ligature-resistant protection while preserving comfort and dignity. Kenall bathroom lighting combines the safety requirements of a high-risk patient environment with the visual comfort and dignity of a residential bathroom, helping patients feel secure and supported during daily personal-care activities.

Explore

Showers & Locker Rooms

Showers & Locker Rooms

Educational locker/shower rooms must balance safety, durability, visibility, hygiene, and comfort. Frequently unsupervised, they are subject to moisture, with a higher risk of slips/falls, accidental impact, and vandalism. Kenall’s Millenium® Series provides uniformity, wet-location protection, glare control, good color rendering, and vandal resistance in locker/shower rooms.

Explore

Stairwells

Stairwells

Hospital stairwells are life-safety spaces first and circulation spaces second. Lighting must support visual comfort, safe movement, emergency egress, security, and code compliance; ensuring occupants can safely navigate stairs during normal operation and emergency evacuation. Kenall’s Millenium® series luminaires offer an attractive solution when performance, aesthetics, maintenance, durability and energy efficiency matter most.

Explore